Just take a vacuum cleaner, turn it on, and blow it on the blocked filter. Now comes the main part of the process, cleaning. Reach out to the filter, grab it tightly with bare hands or with something else, and then lightly pull it out. Rinnai RHFE-1004FA wall heater manual Something went wrong. You basically have to be careful at this point. Take a look at the 4 inches back of the control panel, and you will see the Rinnai heater filter there. Just started today Ask an Expert Home Improvement Questions HVAC Questions Ask Your Own HVAC Question Jeffrey Towler 579 Satisfied Customers Expert Related HVAC Questions satisfied customers Andr R. For this, you have to go to the back of the heater and unscrew the device’s back panel.Īfter this, you will be exposed to a control panel. Rinnai energy saver 1004f fans come on but heat doent kick on shows code 12. You can either pull its cord out of its outlet or press the power button once to turn the device off. You have to turn off the Rinnai heater first. To Conclude: Rinnai Heater Red Flashing Light įor fixing the Rinnai heater red flashing light, here is the step-by-step guide to cleaning the filter.Do I need to service my Rinnai gas heater?.How do you turn on an old Rinnai heater?.Why does my Rinnai heater keep turning off?.A licensed technician should replace any sensitive elements, such as the electronic board or gas valve. If all the above issues are corrected, and the unit is still not operating per specs., the problem might be with the PC electric board and/or gas valve, requiring their replacement.Make sure that the heat exchanger (and space between fins) is clean from debris and dirt, so as the gas burner - to prevent irregular combustion.Check for the proper drainage of the condensate (condensing type).Check for water leaking and excessive moisture as it can lead to corrosion and wet electrical connections.Proper dip switch and gas pressure set up for the high altitude installations.Check the venting system (both intake and exhaust) for blockage.For example, incomplete combustion (not enough fresh air or blockage) leads to incomplete combustion (yellow/red flame instead of blue) and carbon buildup on the flame rods. Always look for the manufacturer's instructions for the correct vent installation, the recommended material, size, length, and proper clearance around the vent.Inspect the flame rod for debris and dirt - clean as needed and replace if there are cracks.Ensure that the flame rod is located correctly and installed tightly in its mounting bracket.Make sure that there is no loose connection in the wiring of the flame rod(s) and that the wiring is plugged into the correct rod.Inspect the igniter and if there is a carbon or scale buildup clean as instructed by the manufacturer.When installing a new element, make sure to install a new gasket too. A loose rod can cause no sparks or create a short if it touches other metal components. The igniter and its ceramic insulation must be securely tightened to the mounting bracket and in the correct position.Verify the correct voltage on the electric board when the unit is in the ignition cycle. If there is no spark, look for the loose, bad, or no connection and the damaged element. Test the unit's igniter for proper work by cycling the unit and checking if there is a spark.Note: As extensive knowledge and skills are needed for any gas work, including the gas license possession, the best is to contact a licensed technician. Ensure that the air is removed (purged) from the gas lines after the installation. Rinnai Space Heaters Sensing Tube A - 1004F-2052-1 - Non-returnable 1004F2052100 View Detail Free Shipping Eligible 7.95 Qty v14895 Rinnai Space Heaters Convection Fan Assembly - 208000061 - Non-returnable Part Works For 208000061000 View Detail Free Ground Shipping 369.There are several causes for the improper gas pressure the gas system was not correctly sized (the manufacturer specs were not met), dirt and debris are present in the system. There must be a proper gas pressure and according to the rating plate.Loose components can cause a short, which will cause the igniter to malfunction. The dip switch on the electronic board must be set for the correct gas type. Check that the igniter is properly and securely affixed to the mounting bracket. The gas type must be according to the rating plate found on the unit.Make sure that there is no interruption in the gas supply to the water heater.Combustion chamber with the ignition rods.Gas installation with the gas regulator.Here is the summary of what can go wrong with your Rinnai water heater and what to look for after the error code 11 shows up on the remote controller. ![]() Check out for possible causes that generate the error code 11 on the digital display of the heater, and explore potential solutions. How to troubleshoot and repair Rinnai water heaters when there is no ignition, followed by the error code 11.
0 Comments
Leave a Reply. |